The MASAI trial in Sweden randomly assigned screening mammograms to AI-supported reading or standard double reading without AI. Transpara scored each exam and routed lower scores to a single reader and the highest score to double reading, with detection marks available on higher-risk exams. This card quotes the prespecified interim safety analysis, not a claim that every screening program should switch.

Entorno clínico

Population mammography screening for women aged 40–80 at four sites in southwest Sweden, inside the existing screening invitation.

Herramientas y proveedores

  • Transpara 1.7.0
  • ScreenPoint Medical

Lo que informó la fuente

In the interim analysis of about 80,000 women (Lancet Oncology, 2023), cancer detection was 6.1 per 1,000 with AI support and 5.1 per 1,000 with standard reading (ratio 1.2, p=0.052). False-positive rates were 1.5% in both arms. Screen-reading workload fell by 44.3%. Interval cancer, the primary endpoint, was left to later follow-up.

Fuente

Lång et al., The Lancet Oncology · 1 ago 2023 · Año 2023

Añadido al índice 28 oct 2026

Abrir fuente

Etiquetas

  • Cribado
  • Visión por computador
  • Lista de trabajo

Ficha para educación y lectura de mercado. No es consejo médico ni un aval.

Imagen y radiología

Regulatorio

Autonomous diabetic retinopathy screening in primary care

IDx-DR, now marketed as LumineticsCore by Digital Diagnostics, was authorized to screen adults with diabetes for more-than-mild diabetic retinopathy without an eye specialist reading the photo first. A primary care team captures images on a specified retinal camera and the software returns a refer-or-rescreen result. It is not a complete eye examination. Pregnancy and several existing retinal conditions sit outside the labeled use.

LumineticsCore (IDx-DR) · Digital Diagnostics · Topcon NW400

Noticia · 2018Leer el caso

Imagen y radiología

Informe del proveedor

Worklist triage for critical findings on chest radiographs

Several cleared products flag possible urgent findings on a chest radiograph, such as pneumothorax, and move that study up a reading worklist. Names often cited for this job include Lunit INSIGHT CXR, Annalise Enterprise CXR, and qXR. This card describes the shared workflow, not a head-to-head, and it does not pool accuracy numbers across vendors. A flagged study still needs a radiologist’s report.

Lunit INSIGHT CXR · Annalise Enterprise CXR · qXR (Qure.ai)

Noticia · 2024Leer el caso

Triaje y urgencias

Regulatorio

Parallel notification of a suspected large-vessel occlusion

Viz.ai ContaCT analyzes brain CT angiography and can text a neurovascular specialist when it suspects a large-vessel occlusion, in parallel with the usual read. FDA permitted marketing in 2018 as notification software. The specialist still reviews full images on a diagnostic workstation. The product is not a diagnosis and not a treatment decision.

Viz.ai ContaCT

Noticia · 2018Leer el caso
Patrocinado

Llegue a lectores clínicos y de tecnología sanitaria.

Ver patrocinio