Adjunct detection on prostate biopsy whole-slide images

監管授權新聞

此語言的正文尚未翻譯,暫以英文顯示。

The source is the U.S. FDA De Novo decision DEN200080 for Paige Prostate, dated 21 September 2021. It authorizes the software as an adjunct that marks a location on a digitized prostate biopsy after the pathologist’s own first look. FDA reported that, across 16 pathologists and 527 slide images, cancer detection on individual slides improved by 7.3% on average versus unassisted reads, with no effect on benign slides. The study did not measure the effect on the final patient diagnosis.

來源日期
2021年9月21日 · 年份 2021
證據標籤
監管授權
來源類型
新聞

完整引用

U.S. FDA De Novo DEN200080

U.S. Food and Drug Administration. De Novo classification request DEN200080, Paige Prostate. Decision date 21 September 2021. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/denovo.cfm?id=DEN200080

已公開的關鍵事實

  • FDA authorized Paige Prostate on 21 September 2021 as an adjunct, not as the diagnosis.
  • The mark is placed on a hematoxylin-and-eosin prostate needle biopsy scanned on a supported whole-slide scanner, after the pathologist’s first look.
  • Across 16 pathologists and 527 slide images, cancer detection on individual slides improved by 7.3% on average versus unassisted reads.
  • The read of benign slides was reported as unaffected.
  • The study did not measure the effect on the final patient diagnosis, which usually rests on more than one core.